Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • DSpace İçeriği
  • Analiz
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Soylak, Mustafa" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    Silica gel-immobilized 5-aminoisophthalohydrazide: A novel sorbent for solid phase extraction of Cu, Zn and Pb from natural water samples
    (Wiley Online Library, 2020-03-11) Aydın, Funda; Çakmak, Reşit; Levent, Abdulkadir; Soylak, Mustafa
    A novel silica sorbent, silica gel‐immobilized 5‐aminoisophthalohydrazide (SiO2‐APH), was prepared by the condensation of 3‐chloropropyl‐functionalized silica gel with 5‐aminoisophthalohydrazide (APH) derived from dimethyl 5‐aminoisophthalate as a starting material and used for separation and preconcentration of Cu, Zn, and Pb metals in water samples using Flame Atomic Absorption Spectrometry (FAAS). The characterization of the new sorbent was carried out by Elemental Analysis, Thermogravimetric Analysis (TGA) and Fourier Transform Infrared Spectroscopy (FTIR). Important analytical parameters including as pH, amount of sorbent, type and amount of eluting solvent, sample volume, vortex and ultrasonic bath time, matrix ions that effect the developed SiO2‐APH‐solid phase extraction (SPE) method were investigated and optimum parameters were detected. Recoveries of examined metals were obtained as 98% for Cu and Pb and 101% for Zn. The relative standard deviation (RSD, n = 8) of Cu, Zn and Pb metals were 3.2, 2.8 and 1.6%, respectively. Limit of detections (LODs) (n = 10) were found as 2.7 μg L−1 for Cu, 7.4 μg L−1 for Zn and 3.5 μg L−1 for Pb μg L−1. The accuracy of the new method was assessed by analyzing of TMDA‐51.4 and TMDA‐70.2 certified reference materials. The results obtained for metals were in a good agreement with certified values. Addition/recovery test was applied to the real well, river, dam and stream water samples to check the accuracy of the method. The results showed that the developed SiO2‐APH‐SPE method can be effectively used as an alternative method for determination of Cu, Zn, and Pb metals in water samples.

| Batman Üniversitesi | Kütüphane | Açık Bilim Politikası | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Batı Raman Kampüsü, Batman, Türkiye
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez ayarları
  • Gizlilik politikası
  • Son Kullanıcı Sözleşmesi
  • Geri bildirim Gönder