Second Law analysis in concentric heat exchangers with vortex flow generators

dc.authorid0000-0002-3349-3409en_US
dc.contributor.authorArgunhan, Zeki
dc.contributor.authorÇakmak, Gülşah
dc.contributor.authorYıldız, Cengiz
dc.contributor.authorBehçet, Rasim
dc.date.accessioned2021-11-26T11:49:31Z
dc.date.available2021-11-26T11:49:31Z
dc.date.issued2011en_US
dc.departmentBatman Üniversitesi Mühendislik - Mimarlık Fakültesi Makine Mühendisliği Bölümüen_US
dc.description.abstractIn the present study, the experimental results of heat transfer of a concentric tube heat exchanger were analyzed with respect to Second Law of Thermodynamics to reach the geometric optimal design of the heat exchangers. In order to increase the heat transfer, the vortex generators were placed in the entrance of the inner pipe of the heat exchanger. These vortex generators are 60 mm in diameter having six angled (55°, 65°, 75°, 90°) winglets. The winglets have one rectangular slot in each and are 2×7 mm in dimensions. Experiments were carried out with different Reynolds Numbers. Air as hot fluid and water as cold fluid were passed through the inner pipe and outer pipe of the concentric tube heat exchanger, respectively. The variations of the efficiency and Entropy Generation Number with respect to Reynolds Number are shown in graphics, and the results were discussed.en_US
dc.identifier.citationArgunhan, Z., Çakmak, G., Yıldız, C., Behçet, R. (2011). Second Law analysis in concentric heat exchangers with vortex flow generators. Energy Education Science and Technology Part A: Energy Science and Research, 28 (1), pp.285-292.en_US
dc.identifier.endpage292en_US
dc.identifier.issue1en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage285en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12402/4111
dc.identifier.volume28en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherEnergy Education Science and Technologyen_US
dc.relation.journalEnergy Education Science and Technology Part A: Energy Science and Researchen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution-NonCommercial-ShareAlike 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.titleSecond Law analysis in concentric heat exchangers with vortex flow generatorsen_US
dc.title.alternativeVorteks akış jeneratörlü eşmerkezli ısı eşanjörlerinde İkinci Kanun analizien_US
dc.typeArticleen_US

Dosyalar

Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: