Numerical analysis of the effect of implant geometry to stress distributions of dental implant system
dc.authorid | 0000-0003-2455-967X | en_US |
dc.contributor.author | Adin, Hamit | |
dc.contributor.author | Topkaya, Tolga | |
dc.contributor.author | Solmaz, Murat Yavuz | |
dc.contributor.author | Dündar, Serkan | |
dc.date.accessioned | 2021-10-14T10:45:28Z | |
dc.date.available | 2021-10-14T10:45:28Z | |
dc.date.issued | 2013-04 | en_US |
dc.department | Batman Üniversitesi Mühendislik - Mimarlık Fakültesi Makine Mühendisliği Bölümü | en_US |
dc.description.abstract | In accordance with the increase in their success rate, dental implants have become a popular treatment option for missing teeth. In long-term clinical application, the survival rate for dental implants is over 90% [1,2]. In general, the success of dental implants is related to the quality and quantity of local bones, implant design and surgical technique. Implant diameter and length are accepted as key factors [3,4]. Present work focuses to investigate the effect of titanium implant geometry to stress distributions around mandible and implant system. For this purpose three different implant models which are currently being used in clinical cases constructed by using ANSYS Workbench 12.1. The stress distributions on components of implant system and mandible under static loading were analyzed for all models | en_US |
dc.description.abstract | Başarı oranlarındaki artışa bağlı olarak diş hekimliği implantlar, eksik dişler için popüler bir tedavi seçeneği haline gelmiştir. İçinde uzun süreli klinik uygulama, diş implantları için hayatta kalma oranı %90'ın üzerinde [1,2]. Genel olarak, diş implantlarının başarısı, yerel kemiklerin kalitesi ve miktarı, implant tasarımı ve cerrahi teknik. İmplant çapı ve uzunluğu temel faktörler olarak kabul edilir [3,4]. Mevcut çalışma titanyumun etkisini araştırmaya odaklanmaktadır. mandibula ve implant çevresindeki stres dağılımlarına implant geometrisi sistem. Bu amaçla üç farklı implant modeli şu anda ANSYS kullanılarak oluşturulan klinik vakalarda kullanılmaktadır. Tezgah 12.1. İmplant bileşenleri üzerindeki stres dağılımları statik yükleme altında sistem ve mandibula tüm modeller | en_US |
dc.identifier.citation | Adin, H., Topkaya, T., Solmaz, M.Y., Dündar, S. (2013). Numerical analysis of the effect of implant geometry to stress distributions of dental implant system. the 11th International Symposium, Computer Methods in Biomechanics and Biomedical Engineering April 3 - 7, 2013, Salt Lake City, Utah, USA | en_US |
dc.identifier.uri | https://hdl.handle.net/20.500.12402/3776 | |
dc.language.iso | en | en_US |
dc.publisher | University of Utah | en_US |
dc.relation.journal | The 11th International Symposium, Computer Methods in Biomechanics and Biomedical Engineering, April 3 - 7, 2013 | en_US |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.rights | Attribution-NonCommercial-ShareAlike 3.0 United States | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/3.0/us/ | * |
dc.title | Numerical analysis of the effect of implant geometry to stress distributions of dental implant system | en_US |
dc.title.alternative | İmplant geometrisinin dental implant sisteminin stres dağılımlarına etkisinin sayısal analizi | en_US |
dc.type | Conference Object | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- Numerical analysis of the effect of implant geometry to stress distributions of dental implant system.pdf
- Boyut:
- 361.68 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text
Lisans paketi
1 - 1 / 1
Küçük Resim Yok
- İsim:
- license.txt
- Boyut:
- 1.44 KB
- Biçim:
- Item-specific license agreed upon to submission
- Açıklama: