Numerical analysis of the effect of implant geometry to stress distributions of dental implant system

dc.authorid0000-0003-2455-967Xen_US
dc.contributor.authorAdin, Hamit
dc.contributor.authorTopkaya, Tolga
dc.contributor.authorSolmaz, Murat Yavuz
dc.contributor.authorDündar, Serkan
dc.date.accessioned2021-10-14T10:45:28Z
dc.date.available2021-10-14T10:45:28Z
dc.date.issued2013-04en_US
dc.departmentBatman Üniversitesi Mühendislik - Mimarlık Fakültesi Makine Mühendisliği Bölümüen_US
dc.description.abstractIn accordance with the increase in their success rate, dental implants have become a popular treatment option for missing teeth. In long-term clinical application, the survival rate for dental implants is over 90% [1,2]. In general, the success of dental implants is related to the quality and quantity of local bones, implant design and surgical technique. Implant diameter and length are accepted as key factors [3,4]. Present work focuses to investigate the effect of titanium implant geometry to stress distributions around mandible and implant system. For this purpose three different implant models which are currently being used in clinical cases constructed by using ANSYS Workbench 12.1. The stress distributions on components of implant system and mandible under static loading were analyzed for all modelsen_US
dc.description.abstractBaşarı oranlarındaki artışa bağlı olarak diş hekimliği implantlar, eksik dişler için popüler bir tedavi seçeneği haline gelmiştir. İçinde uzun süreli klinik uygulama, diş implantları için hayatta kalma oranı %90'ın üzerinde [1,2]. Genel olarak, diş implantlarının başarısı, yerel kemiklerin kalitesi ve miktarı, implant tasarımı ve cerrahi teknik. İmplant çapı ve uzunluğu temel faktörler olarak kabul edilir [3,4]. Mevcut çalışma titanyumun etkisini araştırmaya odaklanmaktadır. mandibula ve implant çevresindeki stres dağılımlarına implant geometrisi sistem. Bu amaçla üç farklı implant modeli şu anda ANSYS kullanılarak oluşturulan klinik vakalarda kullanılmaktadır. Tezgah 12.1. İmplant bileşenleri üzerindeki stres dağılımları statik yükleme altında sistem ve mandibula tüm modelleren_US
dc.identifier.citationAdin, H., Topkaya, T., Solmaz, M.Y., Dündar, S. (2013). Numerical analysis of the effect of implant geometry to stress distributions of dental implant system. the 11th International Symposium, Computer Methods in Biomechanics and Biomedical Engineering April 3 - 7, 2013, Salt Lake City, Utah, USAen_US
dc.identifier.urihttps://hdl.handle.net/20.500.12402/3776
dc.language.isoenen_US
dc.publisherUniversity of Utahen_US
dc.relation.journalThe 11th International Symposium, Computer Methods in Biomechanics and Biomedical Engineering, April 3 - 7, 2013en_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution-NonCommercial-ShareAlike 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.titleNumerical analysis of the effect of implant geometry to stress distributions of dental implant systemen_US
dc.title.alternativeİmplant geometrisinin dental implant sisteminin stres dağılımlarına etkisinin sayısal analizien_US
dc.typeConference Objecten_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Numerical analysis of the effect of implant geometry to stress distributions of dental implant system.pdf
Boyut:
361.68 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: