dc.description.abstract | In this paper, an electrochemical application of bismuth‐film electrode (BiFE) fabricated via ex‐situ electrodeposition onto a glassy carbon electrode for testosterone determination was investigated in aqueous and aqueous/surfactant solutions. In cyclic voltammetry, the compound showed one irreversible and adsorption‐controlled reduction peak. The BiFE revealed good linear response in the examined concentration range of 1 to 45 nmol L−1 testosterone in BrittonRobinson buffer, pH 5.0 containing 3 mmol L−1 cetyltrimethylammonium bromide. The limit of detection was 0.3 nmol L−1 (0.09 ng mL−1). Finally, the BiFE was satisfactorily applied for quantitation of testosterone in both pharmaceutical (oil‐based ampoule) and biological (human urine) samples. | en_US |
dc.identifier.citation | Levent, A., Aitun, A., Taş, S., Yardım, Y., Şentürk, Z. (2015). Voltammetric behavior of testosterone on bismuth film electrode: Highly sensitive determination in pharmaceuticals and human urine by square‐wave adsorptive stripping voltammetry. Electroanalysis, 27 (5), pp. 1219-1228. https://doi.org/10.1002/elan.201400627. | en_US |
dc.identifier.endpage | 1228 | en_US |
dc.identifier.issn | 1521-4109 | |
dc.identifier.issue | 5 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 1219 | en_US |
dc.identifier.uri | https://doi.org/10.1002/elan.201400627 | |
dc.identifier.uri | https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/epdf/10.1002/elan.201400627 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12402/2757 | |
dc.identifier.volume | 27 | en_US |
dc.identifier.wosquality | N/A | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Wiley Online Library | en_US |
dc.relation.isversionof | 10.1002/elan.201400627 | en_US |
dc.relation.journal | Electroanalysis | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.rights | Attribution 3.0 United States | * |
dc.rights.uri | http://creativecommons.org/licenses/by/3.0/us/ | * |
dc.subject | Adsorptive Stripping Voltammetry | en_US |
dc.subject | Bismuth-Film Electrode | en_US |
dc.subject | Cetyltrimethylammonium Bromide | en_US |
dc.subject | Pharmaceutical and Biological Samples | en_US |
dc.subject | Testosterone | en_US |
dc.title | Voltammetric behavior of testosterone on bismuth film electrode: Highly sensitive determination in pharmaceuticals and human urine by square‐wave adsorptive stripping voltammetry | en_US |
dc.type | Article | en_US |