The effect of rotary type turbulator placed in entrance of heat exchanger on heat transfer and frictional loss

dc.authorid0000-0002-3349-3409en_US
dc.contributor.authorArgunhan, Zeki
dc.contributor.authorBehçet, Rasim
dc.contributor.authorYakut, Ali Kemal
dc.date.accessioned2021-11-26T11:34:35Z
dc.date.available2021-11-26T11:34:35Z
dc.date.issued2011en_US
dc.departmentBatman Üniversitesi Mühendislik - Mimarlık Fakültesi Makine Mühendisliği Bölümüen_US
dc.description.abstractIn this study, improving heat transfer in heat exchangers with paralel flow is gained by using swirl flow. For this purpose, a propeller type of turbulator was placed in the entrance of interior pipe of heat exchanger with paralel flow and the effect of turbulator on the heat transfer and friction losses in steady conditions was experimentally investigated. The effect of production of turbulance for improvement of heat transfer in interior pipe flows and the effects of turbulator on heat transfer and pressure drop are experimentally researched by placing a propeller type of turbulator at the entrance of heat exchanger to produce swirl air flow. In experiment setup, water was used as the fluid on which the heat was transferred and air was used as the fluid from which heat was transferred to the water. By usage of datas obtained from experimental measurements were calculated for Reynolds number ranging from 8000 to 24000 necessary relationships effet on heat transfer and pressure drop. In comparison with empty pipe it was seen that the heat transfer increased at range between 25,5%- 50,3% and the friction losses increased 5 times. Besides, by analyzing the system exergy, the dependence of non-dimensional exergy loss on Reynolds number was drawn to investigate whether this improvement technique is advantageous thermodynamically or not. When comparing the exergy losses in empty pipe and the pipe with a turbulator at approximately same Reynolds numbers, it was seen that exergy loss is 15% higher for empty pipe than that for the pipe with the turbulator. As a result of that information, the improvement technique was proved to be advantageous in thermodynamic manner too. By the usage of turbulator that results in the partial recovery of loss energy, it was proven that the improvement technique was thermodynamically advantageousen_US
dc.identifier.citationArgunhan, Z., Behçet, R., Yakut, A.K. (2011). The effect of rotary type turbulator placed in entrance of heat exchanger on heat transfer and frictional loss. Energy Education Science and Technology Part A: Energy Science and Research, 28 (1), pp.239-248.en_US
dc.identifier.endpage248en_US
dc.identifier.issue1en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage239en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12402/4107
dc.identifier.volume28en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherEnergy Education Science and Technologyen_US
dc.relation.journalEnergy Education Science and Technology Part A: Energy Science and Researchen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution-NonCommercial-ShareAlike 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.titleThe effect of rotary type turbulator placed in entrance of heat exchanger on heat transfer and frictional lossen_US
dc.title.alternativeEşanjör girişine yerleştirilen döner tip türbülatörün ısı transferi ve sürtünme kayıplarına etkisien_US
dc.typeArticleen_US