Experimental investigation of thermal performance in a concentric tube heat exchanger with wavy inner pipe
dc.authorid | 0000-0002-3349-3409 | en_US |
dc.contributor.author | Argunhan, Zeki | |
dc.contributor.author | Çakmak, Gülşah | |
dc.contributor.author | Yücel, Halit Lutfi | |
dc.contributor.author | Yıldız, Cengiz | |
dc.date.accessioned | 2021-11-26T10:57:37Z | |
dc.date.available | 2021-11-26T10:57:37Z | |
dc.date.issued | 2012-06 | en_US |
dc.department | Batman Üniversitesi Mühendislik - Mimarlık Fakültesi Makine Mühendisliği Bölümü | en_US |
dc.description.abstract | In this article, the heat transfer, friction factor, and thermal performance factor characteristics of a concentric-tube heat exchanger are examined experimentally. A wavy inner pipe is mounted in the tube with the purpose of generating swirl flow that would help to increase the heat transfer rate of the tube. The examination is performed for a Reynolds number ranging from 2700 to 8800. An empirical correlation is also formulated to match with experimental data of the Nusselt number using the Wilson plot method. In addition, to obtain the real benefits in using the swirl generator at a constant pumping power, the thermal enhancement factor is also determined. Over the range considered, the increases in the Nusselt number, friction factor, and thermal performance factor are found to be, respectively, about 113 %, 81 %, and 196 % higher than those obtained from a smooth-surface inner pipe. | en_US |
dc.identifier.citation | Argunhan, Z., Çakmak, G., Yücel, H.L., Yıldız, C. (2012). Experimental investigation of thermal performance in a concentric tube heat exchanger with wavy inner pipe. International Journal of Thermophysics, 33 (6), pp.1055-1067. DOI:https://dx.doi.org/10.1007/s10765-012-1210-4 | en_US |
dc.identifier.endpage | 1067 | en_US |
dc.identifier.issn | 0195-928X | |
dc.identifier.issue | 6 | en_US |
dc.identifier.scopusquality | Q3 | en_US |
dc.identifier.startpage | 1055 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1007/s10765-012-1210-4 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12402/4103 | |
dc.identifier.volume | 33 | en_US |
dc.identifier.wosquality | Q3 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | SpringerLink | en_US |
dc.relation.isversionof | 10.1007/s10765-012-1210-4 | en_US |
dc.relation.journal | International Journal of Thermophysics | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/restrictedAccess | en_US |
dc.rights | Attribution-NonCommercial-ShareAlike 3.0 United States | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/3.0/us/ | * |
dc.subject | Enhanced Heat Transfer | en_US |
dc.subject | Heat Exchanger | en_US |
dc.subject | Wavy İnner Pipe | en_US |
dc.subject | Wilson Plot Method | en_US |
dc.title | Experimental investigation of thermal performance in a concentric tube heat exchanger with wavy inner pipe | en_US |
dc.title.alternative | Dalgalı iç borulu eşmerkezli borulu bir ısı eşanjöründe termal performansın deneysel incelenmesi | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Küçük Resim Yok
- İsim:
- Experimental investigation of thermal performance in a concentric tube heat exchanger with wavy inner pipe.pdf
- Boyut:
- 486.65 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text
Lisans paketi
1 - 1 / 1
Küçük Resim Yok
- İsim:
- license.txt
- Boyut:
- 1.44 KB
- Biçim:
- Item-specific license agreed upon to submission
- Açıklama: