32 sonuçlar
Arama Sonuçları
Listeleniyor 1 - 10 / 32
Öğe Combustion, performance and emissions of a diesel power generator fueled with biodiesel-kerosene and biodiesel-kerosene-diesel blends(Elsevier, 2017-02-05) Bayındır, Hasan; Işık, Mehmet Zerrakki; Argunhan, Zeki; Yücel, Halit Lütfi; Aydın, HüseyinHigh percentages of biodiesel blends or neat biodiesel cannot be used in diesel engines due to high density and viscosity, and poor atomization properties that lead to some engine operational problems. Biodiesel was produced from canola oil by transesterification process. Test fuels were prepared by blending 80% of the biodiesel with 20% of kerosene (B80&K20) and 80% of the biodiesel with 10% of kerosene and 10% diesel fuel (B80&K10&D10). Fuels were used in a 4 cylinders diesel engine that was loaded with a generator. Combustion, performance and emission characteristics of the blend fuels and D2 in the diesel engine for certain loads of 3.6, 7.2 and 10.8 kW output power and 1500 rpm constant engine speed were experimented and deeply analyzed. It was found that kerosene contained blends had quite similar combustion characteristics with those of D2. Mass fuel consumption and Bscf were slightly increased for blend fuels. HC emissions slightly increased while NOx emissions considerably reduced for blends. It was resulted that high percentages of biodiesel can be a potential substitute for diesel fuel provided that it is used as blending fuel with certain amounts of kerosene.Öğe An experimental investigation of the effect of thermophysical properties on time lag and decrement factor for building elements(Gazi University, 2020-06-01) Oktay, Hasan; Yumrutaş, Recep; Argunhan, ZekiThe time lag (TL) and decrement factor (DF) are essential for the heat storage capabilities of building elements, which strictly depend on the thermophysical properties of the elements. Many investigations are presented in literature arguing to find the influence of each thermophysical property on TL and DF by keeping the other properties constant. This study aims to investigate the effect of each property on TL and DF, utilizing relationships between the measurement values of the thermophysical properties of wall materials. Therefore, first, 132 new concrete wall samples were produced, and their thermophysical properties were tested. Secondly, TL and DF values for each building element are computed from the solution of the problem by Complex Finite Fourier Transform (CFFT) technique. Finally, a multivariate regression analysis has been performed, and the variations of each thermophysical property versus TL and DF are presented, and also the findings are compared with literature. The results show that each property alone (keeping the other properties constant) is not adequate to identify the thermal inertia and thermal performance of a wall element. Besides, 87.3 % decrease in thermal diffusivity corresponds to 6.03 h increase in the value of TL and 88.8 % decrease in value of DF; respectively, for W1 wall assembly.Öğe Çok katmanlı duvar ve çatı tiplerinin ısıl ve fiziksel özelliklerinin dinamik ısıl karakterlerine olan etkisinin incelenmesi(Muğla Sıtkı Koçman Üniversitesi, 2015) Oktay, Hasan; Budak Ziyadanoğulları, Neşe; Argunhan, Zeki; Yumrutaş, Recep; Işık, Mehmet ZerrakkiÖğe The efficiency of Al2O3 water nanofluid on a flat plate solar collector(SETCOR publications, 2015) Budak Ziyadanoğulları, Neşe; Yıldız, Cengiz; Argunhan, Zeki; Tekalp, Selen; Yücel, Halit LutfiSolar collectors are particular kind of heat exchangers that transform solar radiation energy into internal energy of the transport medium. One of the most effective methods is replacing the working fluid (water, ethylene glycol, engine oil…) by developing a new class of fluids with a higher thermal conductivity for thermal systems. In the present work the effect of Al2O3-water, as working fluid, on the efficiency of a flat plate solar collector is investigated experimentally. The mass flow rate of nanofluid is 150 Lit/h. The volume fraction of the nanoparticles is 0.2 %, 0.4 % and 0.8 % respectively. The results reveal the impact and importance of each of these parameters. Experimental results reveal that utilizing the nanofluid increases the collector efficiency in comparison to water as an absorbing mediumÖğe Experimental investigation of solar stills integrated with solar water heating collectors(Türk Isı Bilimi ve Tekniği Derneği, 2017-10-31) Argunhan, Zeki; El, Emin; Yıldız, Cengiz; Çakmak, GülşahSolar still is a more practical way of obtaining clean water. In this study, we aimed to improve the efficiency of solar still systems and obtain distilled water at the same time. For this purpose, 5 different solar still systems were designed. Type 1; conventional solar still, Type 2; conventional solar still integrated with solar water heating collector and run via natural convection, Type 3; conventional solar still integrated with solar water heating collector and tubular heat exchanger and run via natural convection, Type 4; conventional solar still placed with plate heat exchanger and integrated with solar water heating collector and run via natural convection, Type 5; conventional solar still placed with plate heat exchanger and integrated with solar water heating collector and run via forced convection. In this study, the experiments were carried out on the parameters influencing the performance, the amount of distilled water obtained, and the efficiency of experiment settings designed in different types; and finally the results were presented. The amount of distilled water and efficiency of conventional solar still were 2389 ml and 51.47%, respectively. Maximum total amount of water and efficiency from natural convection systems were obtained from Type 4, and the values calculated were found as to be 5788 ml and 55.91%. Maximum amount of distilled water and the efficiency were obtained by utilizing forced convection system were found as to be 6068 ml and 58.99%, respectively.Öğe Dimension and insulation thickness optimization of circular flat plate solar collectors(Energy Education Science and Technology, 2011) Argunhan, ZekiIn this study, expressions for optimum radius of a circular flat plate solar collector and the optimum insulation thickness distribution are derived by using the concept of solar gain, which maximizes the life-cycle savings. For the specified condition the optimum radius has been found as 2.14 m and the optimum insulation thickness distribution on back of collectors has been formulized. The insulation material thickness distribution has been determined by performing a detailed dimensional analysis; therefore heat loss is minimized, and results are presented in graphics.Öğe Konsantrik boru tip ısı değiştiricilerinde türbülatörlerin kanat delik geometrisinin ısı transferine ve basınç düşüşüne etkisi(Fırat Üniversitesi, 2011) Işık, Mehmet Zerrakki; Argunhan, Zeki; Yıldız, CengizThe effect of wing hole geometry of the vortex generator on heat transfer and pressure drop in concentric tube type heat exchangers has been investigated in this study.For experiments, two type of hole geometrywereselected.One has four rectengular hole with 2x7mm in dimension andthe other four circular hole with 5mm in diameter andapplied for 55-65-75-90 degree blade angles. Turbulator diameter is 60 mm and includes 6 blades. Air was used as hot stream, whereas water as cold stream. Experimental results were scrutinized.Heat transfer and pressure drop werefound high with usage of circular holes geometry.Öğe Experimental investigation of the effects of diesel-like fuel obtained from waste lubrication oil on engine performance and exhaust emission(Journals & Books, 2010-10) Argunhan, Zeki; Yumrutaş, Recep; Arpa, OrhanIn this study, effects of diesel-like fuel (DLF) on engine performance and exhaust emission are investigated experimentally. The DLF is produced from waste engine lubrication oil purified from dust, heavy carbon soot, metal particles, gum-type materials and other impurities. A fuel production system mainly consisting of a waste oil storage tank, filters, a reactor, oil pump, a product storage tank, thermostats and control panel is designed and manufactured. The DLF is produced by using the system and applying pyrolitic distillation method. Characteristics, performance and exhaust emissions tests of the produced DLF are carried out at the end of the production. The characteristic tests such as density, viscosity, flash point, heating value, sulfur content and distillation of the DLF sample are performed utilizing test equipments presented in motor laboratory of Mechanical Engineering Department, University of Gaziantep, Turkey. Performance and exhaust emission tests for the DLF are performed using diesel test engine. It is observed from the test results that about 60 cc out of each 100 cc of the waste oil are converted into the DLF. Characteristics and distillation temperatures of the DLF are close to those values of a typical diesel fuel sample. It is observed that the produced DLF can be used in diesel engines without any problem in terms of engine performance. The DLF increases torque, brake mean effective pressure, brake thermal efficiency and decreases brake specific fuel consumption of the engine for full power of operation.Öğe Dairesel kesitli bir borunun girişine yerleştirilen delikli sabit kanatçıklı dönme üreticinin ısı geçişi ve basınç düşüşüne etkileri(Pamukkale Üniversitesi, 2006-02-01) Argunhan, Zeki; Yıldız, CengizBu çalışmada iç içe borulu ısı değiştirgecinde farklı delik sayılı dönme üreticilerin ısı transferine ve basınç düşüşüne etkisi deneysel olarak araştırılmıştır. Bu amaçla değiştirgecin 60 mm çapındaki iç borunun girişine 55º kanat açısına sahip ve kanatlarında birer, ikişer, üçer ve dörder adet dairesel delikler bulunan dönme üreticiler yerleştirilerek deneyler yapılmıştır. Bunlar iç borunun girişine rahat takılıp sökülebilecek şekilde dizayn edilmişlerdir. İç borunun içinden sıcak akışkan olarak hava, iç borunun dışından ise soğuk akışkan olarak su geçmektedir.Öğe An investigation of the influence of thermophysical properties of multilayer walls and roofs on the dynamic thermal characteristics(Mugla Sitki Kocman University, 2016-06-09) Oktay, Hasan; Argunhan, Zeki; Yumrutaş, Recep; Işık, Mehmet Zerrakki; Budak Ziyadanoğulları, NeşeThe growing concern about energy consumption of heating and cooling of buildings has led to a demand for improved thermal performances of building materials. To achieve this goal, in this study, an investigation is performed to analyze the influence of thermophysical properties and thickness of various multilayer building walls or roofs in a building on the dynamic thermal characteristics, such as the decrement factor (DF), time lag (TL) and heat gain. In order to find the thermal performance characteristics of building structures, such as briquette, brick, blockbims and autoclaved aerated concrete (AAC), which are commonly used in Turkey, an analytical solution method was developed in a computer program in MATLAB and results are compared to determine suitable wall or roof material. Calculation method for the heat flow is based on solution of transient heat transfer problem for the multilayer structures. The program is executed to calculate hourly heat gain values for these samples over a period of 24 h during design day for Gaziantep, Turkey. It was found that thermophysical properties of roofs or walls have a very profound effect on the time lag (TL), decrement factor (DF) and also heat gain.