Arama Sonuçları

Listeleniyor 1 - 2 / 2
  • Öğe
    The changes in the serum, liver, kidney protein and genomic DNA profiles in rats treated with 7,12-Dimethylbenz(A) anthracene and Plantago major L.
    (RJPBCS, 2014-01) Berber, İsmet; Ekin, Suat; Levent, Abdulkadir; Oto, Gökhan;
    In the study, the changes in the serum, liver, kidney protein and genomic DNA profiles in Wistar albino rats administrated to 7,12-dimethylbenz(a)anthracene (DMBA) and Plantagomajor L. were investigated. SDS-PAGE profiling of the serum proteins showed that the levels of two proteins molecular weighing 140.8 kDa and 46.8 kDa were significantly lower on the 0th day of treatment than on the 60th day of application in the groups. Furthermore, two proteins (34.5 and 22.3 kDa) were solely present in DMBA-treated liver cell lysates. On the contrary, the kidney protein profiles did not show significant banding variations in groups. Genomic DNA analysis also confirmed that DNA extracted from liver and kidney cells did not fragment in any of the groups after the 60th study day. The proteins 34.5 and 22.3 kDa in liver cell lysates at the 60th day in DMBA-treated group could be extra-prognostic indicators for severe DMBA toxicity.
  • Öğe
    Method validation and simultaneous determination of retinol, retinyl palmitate, β-Carotene, α-Tocopherol and vitamin C in Rat serum treated with 7,12 dimethylbenz[a]anthracene and plantago major L. By high- Performance liquid chromatography using diode-array detection
    (Bentham, 2013-02) Levent, Abdulkadir; Oto, Gökhan; Ekin, Suat; Berber, İsmet
    A new and simple high-performance liquid chromatography method was developed and validated for the simultaneous determination of retinol, retinyl palmitate, β-carotene, α-tocopherol and vitamin C in rat serum treated with Plantago Major L. and 7,12 dimethylbenz[a]anthracene. High-performance liquid chromatography analysis was performed utilizing an Inertsil ODS3 reversed phase column with methanol-tetrahydrofuran-water as mobile phase under gradient conditions, at 1.5 mL min-1 flow rate and 25 °C. Diode-array detection was at 325, 450, 290 and 270 nm (retinol and retinyl palmitate), β-carotene, α-tocopherol and vitamin C, respectively and runnig time 18 min. The high-performance liquid chromatography assay and extraction procedure proposed are simple, rapid, sensitive and accurate. The method was then applied for the determination of retinol, retinyl palmitate, β-carotene, α-tocopherol and vitamin C in rat serum. Results of this study demonstrated that; at 60th day DMBA-treated group, there was a significant decrease in vitamin levels compared to the levels of control group. A significant increase was observed in vitamin levels of 7,12 dimethylbenz[a]anthracene+Plantago Major L.-treated group compared to the DMBA-treated group. Additionally, the results obtained in the study are found to be in agreement with data reported in the literature.