dc.description.abstractThe increased use of power electronic based devices and the nonlinear characteristics of circuit elements used in these devices have led to the formation of harmonic components in power systems. The stable and safe working of power systems depends on the foundation of quantities such as voltage and current, which are sinusoidal and at 50 Hz frequency. However, these foundation quantities lose their sinusoidal characteristics because of many reasons and unwanted harmonic components occur in the off-grid power system. It is highly preferred to use passive LCL filter to reduce the harmonic components that occur in the solar system. The proposed power system is a combination of solar panels, a DC/DC boost converters, solar inverters, six-pulse rectifiers, passive LCL filters and RL inductive loads. A six-pulse uncontrolled rectifier produces 5th, 7th, 11th, 13th, 17th, 19th, etc. Harmonic components. A passive LCL filter is used to reduce the input current of the total harmonic distortion (THDI) of an uncontrolled rectifier. According to these results, the designed passive LCL filters have a simple structure and control is not too complicated provides significant advantages and are not complicated to control, which provides significant advantages. Modelling of off-grid PV power system and simulation was performed with Matlab/Simulink. Simulation results showed that the THDI value reduced from 91.53 % to 2.927%. As a result, LCL filter improves both the system efficiency and reliability of standalone PV power systems.en_US
dc.identifier.citationAdak, S . (2018). Mitigation harmonic with LCL passive filter in off-grid PV system. Journal of Engineering and Technology, 2 (1), 9-20.en_US
dc.identifier.endpage20en_US
dc.identifier.issn2619-9483
dc.identifier.issue1en_US
dc.identifier.startpage9en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12402/2271
dc.identifier.volume2en_US
dc.language.isoenen_US
dc.publisherBatman Üniversitesien_US
dc.relation.journalJournal of Engineering and Technologyen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Başka Kurum Yazarıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution-ShareAlike 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-sa/3.0/us/*
dc.subjectCL Filteren_US
dc.subjectTotal Harmonic Distortion (THD)en_US
dc.subjectOff-Grid PV Systemen_US
dc.subjectHarmonic Mitigationen_US
dc.titleMitigation harmonic with LCL passive filter in off-grid PV systemen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Mitigation Harmonic with LCL Passive Fitler in off-Grid PV System[#454618]-545152.pdf
Boyut:
985.29 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama:

Koleksiyon