Numerical analysis of the effect of implant geometry to stress distributions of the three different commercial dental implant system

dc.authorid0000-0001-6650-8067en_US
dc.contributor.authorTopkaya, Tolga
dc.contributor.authorSolmaz, Murat Yavuz
dc.contributor.authorDündar, Serkan
dc.contributor.authorEltas, Abubekir
dc.date.accessioned2021-11-24T08:44:46Z
dc.date.available2021-11-24T08:44:46Z
dc.date.issued2015-02-11en_US
dc.departmentBatman Üniversitesi Mühendislik - Mimarlık Fakültesi Makine Mühendisliği Bölümüen_US
dc.description.abstractObjectives: The success of dental implants is related to the quality, quantity of local bones, implant design and surgical technique. Implant diameter and length are accepted as key factors. Present work focuses to investigate the effect of titanium implant geometry to stress distributions in implant system. Materials and Methods: For this purpose three different implant models which are currently being used in clinical cases constructed by using ANSYS Workbench 12.1. The stress distributions on components of implant system under static loadings were analyzed for all models. Results: The maximum stress values that occurred in all components happen in the case of loading in which the Nucleoss T-4 (Nucleoss, Turkiye) implant is used, but the occurred lowest stress values happen in the case of Fı loading in which Nobel Active (Nobel Biocare, Zurich, Switzerland) implant is used. In all models, the maximum tensions have occurred in the neck region of the implants. Conclusions: The crestal bone loss in the neck region of the implants reduced the long-term survival rate of implants.The length and the size of the implant are the two important factors in the stress distribution.en_US
dc.identifier.citationTopkaya, T., Solmaz, M.Y., Dündar, S., Eltas, A. (2015). Numerical analysis of the effect of implant geometry to stress distributions of the three different commercial dental implant system. Cumhuriyet Dental Journal, 18 (1), pp.17-24. DOI:https://dx.doi.org/10.7126/cdj.58140.5000037693en_US
dc.identifier.endpage24en_US
dc.identifier.issn1302-5805
dc.identifier.issue1en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage17en_US
dc.identifier.urihttps://dx.doi.org/10.7126/cdj.58140.5000037693
dc.identifier.urihttps://hdl.handle.net/20.500.12402/4061
dc.identifier.volume18en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakTR-Dizinen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherSivas Cumhuriyet Üniversitesien_US
dc.relation.isversionof10.7126/cdj.58140.5000037693en_US
dc.relation.journalCumhuriyet Dental Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution-NonCommercial-ShareAlike 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.subjectFinite Element Analysis (FEA)en_US
dc.subjectDental İmplant Designen_US
dc.subjectStress Distributionen_US
dc.titleNumerical analysis of the effect of implant geometry to stress distributions of the three different commercial dental implant systemen_US
dc.title.alternativeÜç farklı ticari dental implant sisteminin stres dağılımlarına implant geometrisinin etkisinin sayısal analizien_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Numerical analysis of the effect of implant.pdf
Boyut:
1.24 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: