Optimum insulation thickness assessment of different insulation materials for mid-latitude steppe and desert climate (BSH) region of India

Yükleniyor...
Küçük Resim

Tarih

2021-01

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Journals & Books

Erişim Hakkı

info:eu-repo/semantics/restrictedAccess
Attribution-NonCommercial-ShareAlike 3.0 United States

Özet

One of the most effective techniques that is used for energy wastage in buildings is heat insulation. It is possible due to this application to minimize the fuel quantity and accordingly tolerate toxic emissions by finding the optimum point that gives the maximum efficiency. This study was conducted for Jaipur province in Indian climate geography. Climatic characteristics of the region are Mid-Latitude Steppe and Desert Climate (Bsh). Energy need and heat losses in exterior wall were determined by accepting cooling degree day value as T > 24 °C. Optimum insulation thickness, payback period, annual return and annual return rate for XPS and EPS of two different insulating materials respectively are 0.0383–0.0731, 2.35–1.79, 10.95–12.92, 46.84–37.25.

Açıklama

Anahtar Kelimeler

Insulation, Optimum Thickness, Energy Saving, Payback Period, Climatic Zones

Kaynak

WoS Q Değeri

Scopus Q Değeri

Q2

Cilt

44

Sayı

6

Künye

Kallioğlu, M.A., Sharma, A., Chinnasamy, V., Chauhan, R., Singh, T. (2021). Optimum insulation thickness assessment of different insulation materials for mid-latitude steppe and desert climate (BSH) region of India. Materials Today: Proceedings, 44 (6), pp.4421-4424. DOI:https://dx.doi.org/10.1016/j.matpr.2020.10.590