The effect of implant number and position on the stress behavior of mandibular implant retained overdentures: A three-dimensional finite element analysis
Yükleniyor...
Tarih
2015-07-16
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Elsevier
Erişim Hakkı
info:eu-repo/semantics/restrictedAccess
Attribution-NonCommercial-ShareAlike 3.0 United States
Attribution-NonCommercial-ShareAlike 3.0 United States
Özet
The present study evaluated the effects of ball anchor abutment attached to implants with a 4.30 mm diameter and 11 mm insert length on stress distribution in a patient without any remaining teeth in the lower jaw. In the study, the stress analysis was performed for five different configurations (2 with 4 implant-supported and 3 with 2 implant-supported) and three different loading types using ANSYS Workbench software. The stresses measured in the 4 implant-supported models were lower compared to the stresses measured in the 2 implant-supported models. The stresses on the implants intensified on the cervical region of the implants. When the effects of the loading sites on the stress were examined, the loading on the first molar tooth produced the highest stresses on the implants.
Açıklama
Anahtar Kelimeler
Dental Implant, Removable Overdenture, Finite Element Method (FEM)
Kaynak
WoS Q Değeri
N/A
Scopus Q Değeri
N/A
Cilt
48
Sayı
10
Künye
Topkaya, T., Solmaz, M.Y. (2015). The effect of implant number and position on the stress behavior of mandibular implant retained overdentures: A three-dimensional finite element analysis. Journal of Biomechanics, 48 (10), pp.2102-2019. DOI:https://dx.doi.org/10.1016/j.jbiomech.2015.03.006