The effect of implant number and position on the stress behavior of mandibular implant retained overdentures: A three-dimensional finite element analysis
dc.authorid | 0000-0001-6650-8067 | en_US |
dc.contributor.author | Topkaya, Tolga | |
dc.contributor.author | Solmaz, Murat Yavuz | |
dc.date.accessioned | 2021-11-24T08:31:51Z | |
dc.date.available | 2021-11-24T08:31:51Z | |
dc.date.issued | 2015-07-16 | en_US |
dc.department | Batman Üniversitesi Mühendislik - Mimarlık Fakültesi Makine Mühendisliği Bölümü | en_US |
dc.description.abstract | The present study evaluated the effects of ball anchor abutment attached to implants with a 4.30 mm diameter and 11 mm insert length on stress distribution in a patient without any remaining teeth in the lower jaw. In the study, the stress analysis was performed for five different configurations (2 with 4 implant-supported and 3 with 2 implant-supported) and three different loading types using ANSYS Workbench software. The stresses measured in the 4 implant-supported models were lower compared to the stresses measured in the 2 implant-supported models. The stresses on the implants intensified on the cervical region of the implants. When the effects of the loading sites on the stress were examined, the loading on the first molar tooth produced the highest stresses on the implants. | en_US |
dc.identifier.citation | Topkaya, T., Solmaz, M.Y. (2015). The effect of implant number and position on the stress behavior of mandibular implant retained overdentures: A three-dimensional finite element analysis. Journal of Biomechanics, 48 (10), pp.2102-2019. DOI:https://dx.doi.org/10.1016/j.jbiomech.2015.03.006 | en_US |
dc.identifier.endpage | 2109 | en_US |
dc.identifier.issn | 00219290 | |
dc.identifier.issue | 10 | en_US |
dc.identifier.scopusquality | N/A | en_US |
dc.identifier.startpage | 2102 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1016/j.jbiomech.2015.03.006 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12402/4060 | |
dc.identifier.volume | 48 | en_US |
dc.identifier.wosquality | N/A | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier | en_US |
dc.relation.isversionof | 10.1016/j.jbiomech.2015.03.006 | en_US |
dc.relation.journal | Journal of Biomechanics | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/restrictedAccess | en_US |
dc.rights | Attribution-NonCommercial-ShareAlike 3.0 United States | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/3.0/us/ | * |
dc.subject | Dental Implant | en_US |
dc.subject | Removable Overdenture | en_US |
dc.subject | Finite Element Method (FEM) | en_US |
dc.title | The effect of implant number and position on the stress behavior of mandibular implant retained overdentures: A three-dimensional finite element analysis | en_US |
dc.title.alternative | Mandibular implant destekli diş üstü protezlerin stres davranışına implant sayısı ve pozisyonunun etkisi: Üç boyutlu bir sonlu eleman analizi | en_US |
dc.type | Conference Object | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Küçük Resim Yok
- Ä°sim:
- The effect of implant number and position on the stress behavior of mandibular implant retained overdentures.pdf
- Boyut:
- 8.47 MB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text
Lisans paketi
1 - 1 / 1
Küçük Resim Yok
- Ä°sim:
- license.txt
- Boyut:
- 1.44 KB
- Biçim:
- Item-specific license agreed upon to submission
- Açıklama: