Arama Sonuçları

Listeleniyor 1 - 3 / 3
  • Öğe
    Method validation and simultaneous determination of retinol, retinyl palmitate, β-Carotene, α-Tocopherol and vitamin C in Rat serum treated with 7,12 dimethylbenz[a]anthracene and plantago major L. By high- Performance liquid chromatography using diode-array detection
    (Bentham, 2013-02) Levent, Abdulkadir; Oto, Gökhan; Ekin, Suat; Berber, İsmet
    A new and simple high-performance liquid chromatography method was developed and validated for the simultaneous determination of retinol, retinyl palmitate, β-carotene, α-tocopherol and vitamin C in rat serum treated with Plantago Major L. and 7,12 dimethylbenz[a]anthracene. High-performance liquid chromatography analysis was performed utilizing an Inertsil ODS3 reversed phase column with methanol-tetrahydrofuran-water as mobile phase under gradient conditions, at 1.5 mL min-1 flow rate and 25 °C. Diode-array detection was at 325, 450, 290 and 270 nm (retinol and retinyl palmitate), β-carotene, α-tocopherol and vitamin C, respectively and runnig time 18 min. The high-performance liquid chromatography assay and extraction procedure proposed are simple, rapid, sensitive and accurate. The method was then applied for the determination of retinol, retinyl palmitate, β-carotene, α-tocopherol and vitamin C in rat serum. Results of this study demonstrated that; at 60th day DMBA-treated group, there was a significant decrease in vitamin levels compared to the levels of control group. A significant increase was observed in vitamin levels of 7,12 dimethylbenz[a]anthracene+Plantago Major L.-treated group compared to the DMBA-treated group. Additionally, the results obtained in the study are found to be in agreement with data reported in the literature.
  • Öğe
    Determination of 7,12-dimethylbenz[a]anthracene in orally treated rats by high-performance liquid chromatography and transfer stripping voltammetry
    (Bentham, 2012-06) Yardım, Yavuz; Levent, Abdulkadir; Ekin, Suat; Keskin, Ertuğrul; Oto, Gökhan; Şentürk, Zühre
    A number of polycyclic aromatic hydrocarbons (PAHs) have been shown to be toxicants, and induce carcinogenic and immunotoxic effects. As a model PAH agent, 7,12-dimethylbenz[a]anthracene (DMBA) was the strongest one tested in terms of its biological activities and biotransformation. A new and simple high-performance liquid chromatographic (HPLC) method with diode-array detection at 290 nm was developed and validated for monitoring of DMBA in different matrices (serum, liver and kidney) of rats orally treated with DMBA. Furthermore, the applicability of adsorptive transfer stripping voltammetry (AdTSV) on the pencil-lead graphite electrode to these samples was illustrated using our previously reported data for bulk aqueous solutions of DMBA. HPLC and AdTSV methods, which were compatible with each other, allowed DMBA to be detected down to the levels of 3.82x10-9 M (0.98 ppb) and 6.73x10-9 M (1.73 ppb), respectively. Olive oil solutions of DMBA in dose 50 mg/kg were orally administered. 60 days after a single dose of DMBA, its concentrations in these biological samples from rats were measured by means of both methods. Because of rapid biotransformation, DMBA could not be detected in serum. Only low levels of the compounds were deposited unchanged in kidney whereas its levels were considerably higher in liver. These methods were also applied to the assay whether there is an influence of the intake of aqueous extracts of Hypericum Perforatum L. plant on the parent DMBA levels accumulated in rat tissues.
  • Öğe
    Protective effect of Hypericum perforatum L. on serum and hair trace elements in rats 7,12-dimethylbenz[a]anthracene-induced oxidative stress
    (Elsevier, 2012-02-08) Ekin, Suat; Yardım, Yavuz; Oto, Gökhan; Levent, Abdulkadir; Özgökçe, Fevzi; Kusman, Tuba
    The study was designed to assess the effect of Hypericum perforatum L. (H.P) on serum and hair trace elements and mineral levels, oral administration of 7,12-dimethylbenz[a]anthracene (DMBA) induced oxidative stress in Sprague-Dawley female rats. Analysis of the trace element has been carried out using atomic absorption spectrophotometer method at end of 60th day. It has been found out that the DMBA group contained statistically lower Zn and Cr compared to the control group (p < 0.01) and (p < 0.05), Cu, Mg and Na contained higher than control group (p < 0.05), (p < 0.05) and (p < 0.05). In DMBA + H.P group, Zn higher and Na lower than DMBA group (p < 0.05), (p < 0.05), in hair samples Cd, K and Zn contained lower DMBA compared to the control group (p < 0.05), (p < 0.05) and (p < 0.05). In group DMBA + H.P, Cd was higher than DMBA group and Cr lowered accordance with control group (p < 0.05). The present study demonstrated significantly positive and beneficial effect of H.P on the concentration levels of Zn and Na in serum, also on Cd levels in hair between DMBA and DMBA + H.P groups.