2 sonuçlar
Arama Sonuçları
Listeleniyor 1 - 2 / 2
Öğe Simultaneous electrochemical evaluation of ascorbic acid, epinephrine and uric acid at disposable pencil graphite electrode: Highly sensitive determination in pharmaceuticals and biological liquids by differential pulse voltammetry(Elsevier, 2018) Levent, Abdulkadir; Önal, GünayAim and Objective: As is known, AA, EP and UA can also coexist in biological fluids. Therefore, the determination of the levels of these compounds in biological fluids is extremely important both for the diagnosis and treatment of the related diseases. In the presence of many interfering substances in biological fluids such as blood and urine samples, it is very important that these compounds can be selectively analyzed. Materials and Methods: All electrochemical experiments were performed using an Autolab PGSTAT 128N potentiostat. Before beginning the electrochemical measurements, the PGE was activated. The electrochemical pretreatment of PG was exercised by anodically +1.40 V for 60 s. Then, measurements were performed with CV (-0.4 V to 1.2 V) and DPV (-0.2 V to 0.7 V) for single and simultaneous voltammetric behaviour of AA, EP, and UA in the electrochemical method. Results: The anodic peak potentials of AA and UA were observed at about +0.32 V and +0.62 V, respectively. On the other hand, for EP, while anodic peak potential was observed at about +0.53 V, in the reverse scan, cathodic peak potentials were observed at about +0.41 V and +0.007 V. The39 reduction peak observed at +0.3 V with the oxidation peak observed at +0.53 V are the reversible peaks. In the method developed for the electrochemical simultaneous determination of AA, EP and UA using PGE with DPV technique in BR buffer solution (pH 4.0), the anodic peak potentials are sufficiently separated from each other. Conclusion: A voltammetric method was developed for the simultaneous determination of AA, EP and UA with PGE for the first time. Here, the most important thing is that the simultaneous determination of AA, EP and UA was successfully achieved with that targeted voltammetric method which was sensitive, low-cost, practical and well-repeated; and that these were proven to be selectively applicable in pharmaceutical products and biological liquids.Öğe Application of a pencil graphite electrode for voltammetric simultaneous determination of ascorbic acid, norepinephrine, and uric acid in real samples(TÜBİTAK, 2018-04-27) Levent, Abdulkadir; Önal, GünayA pencil graphite electrode (PGE) was used for the simultaneous detection of ascorbic acid (AA), norepinephrine (NE), and uric acid (UA) by differential pulse voltammetry and cyclic voltammetry. The anodic peaks of AA, NE, and UA in their mixture can be well separated in 0.1 M Britton–Robinson buffer solution at pH 4.0. The effects of various experimental parameters such as pH, scan rate, and voltammetric parameters on the voltammetric response of these compounds were investigated. Under optimum conditions, linear calibration graphs were obtained from the AA, NE, and UA concentration ranges, which were 100–800 nM, 20–170 nM, and 40–175 nM, respectively. The detection limits for AA, NE, and UA were 27 nM, 4 nM, and 10 nM in the form of a mixture at the PGE. This electrode shows great analytical performance characteristics, corresponding repeatability and recovery for the simultaneous determination of these compounds. PGE, which was used for the first time in this method, has been successfully applied for the assay of UA in human urine samples with the aim of determining AA and NE in pharmaceutical drugs.