Arama Sonuçları

Listeleniyor 1 - 6 / 6
  • Öğe
    Electrochemical performance of boron-doped diamond electrode in surfactant-containing media for ambroxol determination
    (Elsevier, 2014-07-17) Levent, Abdulkadir; Yardım, Yavuz; Şentürk, Zühre
    A novel application of boron-doped diamond electrode is introduced for the determination of ambroxol, a potential antioxidant drug belonging to the expectorant class. The electrochemical oxidation of ambroxol was first investigated by cyclic voltammetry using boron-doped diamond and glassy carbon electrodes in aqueous solutions both with and without the addition of surfactant. The compound was irreversibly oxidized in one/two steps at high positive potentials, resulting in the formation of a couple with a reduction and re-oxidation wave at less positive potentials. Special attention was given to the use of adsorptive stripping voltammetry at a surface of mildly oxidized boron-doped diamond electrode in aqueous solutions over the pH range of 1.0–10.0. Addition of anionic surfactant (sodium dodecylsulfate) to ambroxol-containing electrolyte enhanced the stripping current signal. Using square-wave stripping mode, the drug yielded a well-defined voltammetric response in phosphate buffer pH 2.5 containing 4 × 10−4 M sodium dodecylsulfate at +1.02 V (versus Ag/AgCl) (after 30 s accumulation at +0.50 V). The process could be used to determine ambroxol in the concentration range of 0.05–0.7 μM, with a detection limit of 0.010 μM (4.2 ng mL−1). The suggested method was successfully applied to pharmaceuticals and spiked human urine samples.
  • Öğe
    Electroanalytical determination of progesterone hormone using borondoped diamond electrode
    (ICNTC, 2020) Levent, Abdulkadir; Uçar, Muhlis
    Progesterone is synthesized from pregnenolone, a derivative of cholesterol like other steroids. It is a steroid hormone that has a vital importance in human and animal health. In case of progesterone imbalance, it causes problems such as fertility and infertility. In this study, electrochemical properties of Progesterone hormone Boron doped diamond (BDD) on electrode surface were investigated in strongly acidic environment (HClO4 and H2SO4). A fast, sensitive, selective and simple electroanalytical method was developed for cathodically pre-treated BDD electrodes. A good linear analytical curve in the concentration range of 10 μM to 100 μM at a voltage value of +1.51 V (vs. Ag / AgCl) (after 120 s deposition at +0.1 V voltage) in 0.5 M HClO4 using the square wave stripping technique for the quantification of progesterone hormone obtained. The observability limit is 0.012 µM(3.77 µg L-1); The relative standard deviation value (RSD) for the concentration of 3.1 µM (n = 11) was calculated to be 4.87%. In addition, the developed voltammetric method has been successfully applied to drug and blood serum.
  • Öğe
    Bor katkılı elmas elektrot kullanarak progesteron hormonunun elektroanalitik incelenmesi
    (Batman Üniversitesi Fen Bilimleri Enstitüsü, 2019-11-19) Uçar, Muhlis; Levent, Abdulkadir
    Bu tez çalışmasında, Progesteron hormonu Bor katkılı elmas(BDD) elektrot yüzeyinde elektrokimyasal özellikleri, kuvvetli asidik ortamda (HClO4 ve H2SO4) incelenmiştir. Katodik olarak önişlem görmüş BDD elektrot ile hızlı, duyarlı, seçici ve basit bir elektroanalitik yöntem geliştirilmiştir. Kare dalga sıyırma tekniği kullanarak progesteron hormonunun miktar tayinini 0.5 M HClO4 destek elektrolit çözeltisinde +1.51 V (vs. Ag/AgCl) gerilim değerinde (+0.1 V gerilimde 120 s biriktirme sonrası) 0.1-7.1 μM derişim aralığında geniş bir analitik çalışma aralığı elde edilmiştir. Gözlenebilirlik sınırı 0.012 µM (3.77 µg L-1) olup; 3.1 µM (n=11) derişim değeri için bağıl standart sapma değeri (RSD), %4.87 olarak hesaplanmıştır. Geliştirilen voltametrik yöntem ilaç ve kan serum numunelere başarılı bir şekilde uygulanmıştır.
  • Öğe
    Electrochemical determination of melatonin hormone using a boron-doped diamond electrode
    (Elsevier, 2012-01) Levent, Abdulkadir
    In this study, a boron-doped diamond electrode was used for the electroanalytical determination of melatonin in the pharmaceutical tablet and urine samples by square-wave voltammetry. Melatonin yielded a well-defined voltammetric response in Britton-Robinson buffer, pH 3.0 at + 0.88 V (vs. Ag/AgCl). Using the optimal square-wave voltammetry conditions, the oxidation peak was used to determine melatonin in the concentration range of 5.0 × 107 M to 4.0 × 106 M (r = 0.998, n = 8), a detection limit of 1.1 × 107 M (0.025 μg/mL) and relative standard deviation was 2.06% at the 2.0 × 106 M level (n = 10). Recoveries of melatonin were in the range of 97.67–105%, for both tablet and spiked human urine samples.
  • Öğe
    Voltammetric behavior of benzo[a]pyrene at boron-doped diamond electrode: A study of its determination by adsorptive transfer stripping voltammetry based on the enhancement effect of anionic surfactant, sodium dodecylsulfate
    (Elsevier, 2011-07-15) Yardım, Yavuz; Keskin, Ertuğrul; Levent, Abdulkadir; Şentürk, Zühre
    Benzo[a]pyrene (BaP), a member of the polycyclic aromatic hydrocarbon (PAH) class, is one of the most potent PAH carcinogens. The electrochemical oxidation of BaP was first studied by cyclic voltammetry at the boron-doped diamond electrode in non-aqueous solvent (dimethylsulphoxide with lithium perchlorate). The compound was irreversibly oxidized in a single step at high positive potential, resulting in the well-resolved formation of a couple with a reduction and re-oxidation wave at much lower potentials. Special attention was given to the use of adsorptive stripping voltammetry together with a medium exchange procedure in aqueous and aqueous/surfactant solutions over the pH range of 2.0–8.0. The technique in aqueous solutions had little value in practice because of too small oxidation peak current. This problem was solved when surfactants were added into the sample solution, by which the oxidation peak currents of BaP were found enhanced dramatically. The employed surfactants were sodium dodecylsulfate (anionic, SDS), cetyltrimethylammonium bromide (cationic, CTAB) and Tween 80 (non-ionic). Using square-wave stripping mode, the compound yielded a well-defined voltammetric response in Britton–Robinson buffer, pH 2.0 containing 2.5 × 10−4 M SDS at +1.07 V (vs. Ag/AgCl) (after 120 s accumulation at +0.10 V). The process could be used to determine BaP in the concentration range of 16–200 nM (4.04–50.46 ng mL−1), with a detection limit of 2.86 nM (0.72 ng mL−1). This method was also applied to determine BaP in model water sample prepared by adding its different concentrations into tap water.
  • Öğe
    Hodgkin lenfoma tedavisinde kullanılan brentuksimab vedotin’in elektrokimyasal özelliklerinin incelenmesi ve miktar tayini için bor-katkılı elmas elektrot uygulaması
    (Batman Üniversitesi Lisansüstü Eğitim Enstitüsü, 2024-12-24) Karadoğan, Abdülsemet; Levent, Abdulkadir
    Sunulan tez çalışmasında, Hodgkin lenfoma tedavisinde kullanılan bir antikanser ilaç olan Brentuksimab vedotin’in elektrokimyasal tayini için Bor-katkılı elmas elektrodun kullanımına dayanan yeni bir elektroanalitik teknik geliştirilmiştir. Geliştirilen bu elektroanalitik teknikte, sülfürik asit ortamında elektrokimyasal olarak aktive edilen bor-katkılı elmas elektrot üzerinde, özellikle bazik ortamda Brentuksimab vedotin’in döngülü voltametri tekniği ile yaklaşık +1.35 V civarında tersinmez bir dalga verdiği görülmüştür. Brentuksimab vedotin’in kantitatif tayini için geliştirilen teknikte, Britton-robinson (pH =8.0) destekleyici elektrolit ortamında bor-katkılı elmas elektrot üzerinde 9.99 μg/mL ile 49.95 μg/mL derişim aralığındaki doğrusal denklem Ip(μA)=0.026 C[BV] (μg/mL) -0.269, r=0.997 (n=9) olarak belirlenmiştir. Geliştirilen yöntemin en düşük tayin alt sınırı 0.98 μg/mL olarak hesaplandı. Ayrıca geliştirilen metod idrar numunelerine standart ekleme-geri kazanma işlemi uygulanarak metodun doğruluk çalışması yapılmıştır. Yapılan analizler sonucunda idrar örneklerinde bulunan Brentuksimab vedotin için % 94.25’lik yüksek bir geri kazanım sonucu elde edilmiştir. Bu da idrarda bulunan Brentuksimab vedotin’in tayini için geliştirdiğimiz elektrokimyasal metodun yüksek doğrulukla sonuç üretebildiğini göstermiştir.